;WS: wrong scale for current setting corrected, max current corrected from 6 to 6.1A, misleading note removed

#metadef
#author MikeLud
#idString Riden,Riden RD6006
#name Riden RD6006
#handle RD6006
#replacetext RD60xx 60062
#removeline 12A
#replaceText MaxCurrent 6.100
#replaceText MaxOCP 6.200
#replaceText CurrentScaleFactor 1000

#metadef
#author MikeLud
#idString Riden,Riden RD6012
#name Riden RD6012
#handle RD6012
#replacetext RD60xx 60121
#replaceText MaxCurrent 12.000
#replaceText MaxOCP 12.100
#replaceText CurrentScaleFactor 100

#metadef
#idString Riden,Riden RD6018
#name Riden RD6018
#handle RD6018
#replacetext RD60xx 60181
#replaceText MaxCurrent 18.100
#replaceText MaxOCP 18.200
#replaceText CurrentScaleFactor 100


#meta
#author MikeLud
#idString Riden,Riden RD60xx
#name Riden RD60xx
#handle RD60xx
#port comfixedbaud
#baudrate 115200
#driver Modbus

#verifyDevice RD60xx Model?

#scpiCmd SysTC? holding? 0x05
#scpiCmd VSet holding 0x08 (value) *100
#scpiCmd VSet? holding? 0x08 /100
#scpiCmd ISet holding 0x09 (value) *CurrentScaleFactor
#scpiCmd ISet? holding? 0x09 /CurrentScaleFactor
#scpiCmd VOut? holding? 0x0a /100
#scpiCmd IOut? holding? 0x0B /100
#scpiCmd Watt? holding? 0x0D /100
#scpiCmd ERROR? holding? 0x10
#scpiCmd MODE? holding? 0x11
#scpiCmd OUTPUT? holding? 0x12
#scpiCmd OUTPUT holding 0x12 (value)
#scpiCmd MEM? holding? 0x13
#scpiCmd MEM holding 0x13 (value)
#scpiCmd BattM? holding? 0x20
#scpiCmd BattV? holding? 0x21 /100
#scpiCmd BattT? holding? 0x23
#scpiCmd Ah? holdingl? 0x26 /1000
#scpiCmd Wh? holdingl? 0x28 /1000
#scpiCmd TakeOK? holding? 0x42
#scpiCmd TakeOK holding 0x42 (value)
#scpiCmd TakeOut? holding? 0x43
#scpiCmd TakeOut holding 0x43 (value)
#scpiCmd BootP? holding? 0x44
#scpiCmd BootP holding 0x44 (value)
#scpiCmd Buzzer? holding? 0x45
#scpiCmd Buzzer holding 0x45 (value)
#scpiCmd Logo? holding? 0x46
#scpiCmd Logo holding 0x46 (value)
#scpiCmd BL? holding? 0x48
#scpiCmd BL holding 0x48 (value)
#scpiCmd M0OVP? holding? 0x52 /100
#scpiCmd M0OVP holding 0x52 (value) *100
#scpiCmd M0OCP? holding? 0x53 /1000
#scpiCmd M0OCP holding 0x53 (value) *1000
#scpiCmd MN? holding? 0x80
:setvar: MNS=int(value)
#scpiCmd MN holding 0x80 (value)
#scpiCmd MV? holding? (MNS) /100
#scpiCmd MV holding (MNS) (value) *100
#scpiCmd MI? holding? (MNS+1) /CurrentScaleFactor
#scpiCmd MI holding (MNS+1) (value) *CurrentScaleFactor
#scpiCmd OVP? holding? (MNS+2) /100
#scpiCmd OVP holding (MNS+2) (value) *100
#scpiCmd OCP? holding? (MNS+3) /1000
#scpiCmd OCP holding (MNS+3) (value) *1000

#scpiCmd values? holding? 0x08 /100;holding? 0x09 /CurrentScaleFactor;holding? 0x0A /100;holding? 0x0B /CurrentScaleFactor;holding? 0x0D /100;holding? 0x21 /100;holding? 0x23;holdingl? 0x26 /1000;holdingl? 0x28 /1000

#scpiCmd model? holding? 0x00
#scpiCmd getDeviceSW? holding? 0x03 /100
#scpiCmd getDeviceSN? holdingl? 0x01



; A list of possible column name with unit and formatter (SI, Time, Int, D0..D6)
#value VoltageSet V D 
#value CurrentSet A D3
#value Voltage V D2 
#value Current A D3 
#value Power W D2
#value BatteryVoltage V D2
#value BatteryTemp °C D0
#value AmpH Ah D3
#value WattH Wh D3
 

; This is a single line command
#askValues values?

;Accept this delay when reading values (seconds)
#readingDelay 5

; Initial commands to meter when establishing connection
#initCmd MN?

; Final command to meter before breaking connection
#finalCmd OUTPUT 0

; Used when output off button is pressed
#outputOff OUTPUT 0

#interfaceType PS
#interface setVoltage VSet (value)
#interface setCurrent ISet (value)
#interface setOn OUTPUT (value)
#interface getVoltage VOut?
#interface getCurrent IOut?
#interface getOn OUTPUT?
#interface readVoltage 0
#interface readCurrent 1



; Strings to configure device in different modes
; First parameter must match a #value (4 parameter) and second parameter must match what #askMode returns
; First parameter is also used in shortcut menu
;#cmdMode 

; Setup menu functions
; The parameters on the first line is: type name page 
; Settings on the following lines are:
; read: SCPI to read value from device, is used to synchronize when opening setup page or setting equal named fields. Not always used
; readformat: Parse read value.
; write: Send the value to device, this field is used in combination with data fields in the details to send updates to device.
; tip: Add this tip to all components for this input field.

#cmdSetup buttonsOn Output
:read: OUTPUT?
:write: OUTPUT 
:tip: Turn output on or off
:updatealloff:
:update: Output
:updatedelayed: 0.3 
Off 0
On 1

#cmdSetup radio Voltage Main 
:read: VSet?
:write: VSet
:update: Voltage
:update: 0.3 
:tip: Setup this voltage
3.3V 3.3
5V 5.0
12V 12.0
24V 24.0
48V 48.0
60V 60.0

#cmdSetup radio Current Main 
:read: ISet?
:write: ISet
:update: Current
:updatedelayed: 0.3 
:tip: Output will current limit at this current
100mA 0.1
250mA 0.25
500mA 0.5
1A 1.0
3A 3.0
6A 6.0
12A 12.0

#cmdSetup number Voltage Main 
:read: VSet?
:write: VSet
:tip: Setting this voltage, does not turn output on/off
V 0.00 60.00

#cmdSetup number Current Main
:read: ISet?
:write: ISet
:tip: Setting this current, does not turn output on/off
A 0.000 MaxCurrent

#cmdSetup combobox Memory Main
:read: MEM?
:write: MEM 
:tip: Setting this memory, turns output off
:update: Voltage Current
:updatedelayed: 0.3 
M0 0
M1 1
M2 2
M3 3
M4 4
M5 5
M6 6
M7 7
M8 8
M9 9

#cmdSetup indicatornum Status Main
:read: Mode?
CV 0 blue
CC 1 red

#cmdSetup indicatornum Status Main
:read: ERROR?
OK 0 blue
OVP 1 red
OCP 2 red

#cmdSetup indicatornum Status Main
:read: BattM?
Batt_Mode_Off 0 blue
Batt_Mode_On 1 red

;#cmdSetup Updater update
;:update: Status
;2

#cmdSetup number OVP Limits
:read: M0OVP?
:write: M0OVP
:tip: Output will turn off if it is above this voltage
V 0 62

#cmdSetup number OCP Limits
:read: M0OCP?
:write: M0OCP
:tip: Output will turn off if it is above this voltage
A 0 MaxOCP

#cmdSetup radio Take_Ok Settings
:read: TakeOK?
:write: TakeOK
:tip: Turn on the “Take OK”, a confirmation window will pop up when you quick call out a data group.
On 1
Off 0

#cmdSetup radio Take_Out Settings
:read: TakeOut?
:write: TakeOut
:tip: Turn on the “Take out”, the output will be turn on automatically when you call out a data group
On 1
Off 0

#cmdSetup radio Boot_Power Settings
:read: BootP?
:write: BootP
:tip: Turn on the “Boot Power”, it will turn on the output automatically when started
On 1
Off 0

#cmdSetup radio Buzzer Settings
:read: Buzzer?
:write: Buzzer
:tip: Turn on the “Buzzer”, you will hear button tune when press the buttons
On 1
Off 0

#cmdSetup radio Logo Settings
:read: Logo?
:write: Logo
:tip: Turn on the “Logo”, it will display Logo first when booting up
On 1
Off 0

#cmdSetup slider Backlight Settings
:read: BL?
:write: BL
:tip: 0=Minimal brightness, 5=Maximal brightness
_ 0 5

#cmdSetup comboboxhot Memory Memory
:read: MN?
:write: MN
:update: V-Set I-Set OVP OCP
:updatedelayed: 0.3
M0 80
M1 84
M2 88
M3 92
M4 96
M5 100
M6 104
M7 108
M8 112
M9 116

#cmdSetup number V-Set Memory
:read: MV?
:write: MV
:tip: Output will turn off if it is above this voltage
V 0 60

#cmdSetup number I-Set Memory
:read: MI?
:write: MI
:tip: Output will turn off if it is above this voltage
V 0 MaxCurrent

#cmdSetup number OVP Memory
:read: OVP?
:write: OVP
:tip: Output will turn off if it is above this voltage
V 0 62

#cmdSetup number OCP Memory
:read: OCP?
:write: OCP
:tip: Output will turn off if it is above this voltage
V 0 MaxOCP